Search
Recommend This Site
Social Networks
Recent Tweets
« Determination of Free Acidity as Hydrochloric Acid in Ferric Chloride Solution RDM-5007 | Main | Determination of Free Acidity as Hydrochloric Acid in Ferric Chloride Solution RDM-5003 »
Friday
Dec112009

Determination of Free Acidity as Hydrochloric Acid in Ferric Chloride Solution RDM-5006

RD Chemical Logo

Determination of Free Acidity as Hydrochloric Acid in Ferric Chloride Solution (RDM-5006)

Procedure for Analysis

Theory:
Ferric iron is complexed with Potassium Fluoride to prevent hydrolysis. The free acid is then titrated with standard Sodium Hydroxide to an electrometric end point.

Reagents Required:

  • Sodium Hydroxide, standard 0.10N solution.
  • 33% Potassium Fluoride (anhyd), or 50% KF.2H2O neutralized to Phenolphthalein endpoint.
  • Methanol


Equipment Required:

  • pH meter, preferably with electrode that can tolerate immersion in HF
  • magnetic stirrer
  • Buret

Procedure:

  • 1. In 150 ml beaker, weigh accurately 1-2 grams of ferric chloride solution. Add 50 ml Methanol.
  • 2. Add 25 ml of Potassium Fluoride solution and mix.
  • 3. Put pH probe into solution, and note initial reading, may use either pH or mVolt readings.
  • 4. Titrate with standard NaOH until readings increase dramatically, noting pH meter reading after each aliquot of NaOH is added.
  • 5. Plot mls NaOH added vs meter readings. Note mls added in area of greatest change of readings, use these mls for calculation below.



Calculation:
% Free acidity as HCl = mls 0.1N NaOH x 0.3645 grams of sample

RD Chemical presents these procedures in good faith, based on laboratory and field testing. Ultimate responsibility for propriety of use, however, must rest with the purchaser and user. RD Chemical Company recommends thorough testing of its products and procedures before use.

PrintView Printer Friendly Version

EmailEmail Article to Friend